Digital Industrial X-Ray : |
| |
| |
| |
|
| |
|
| |
|
| |
| |
Vision VIX 1605 Online Industrial X-ray Inspections system designed equipment for inspection of different types of castings. The system combines the advantage of highly efficient detectors, digital image processing, computer graphics and smart algorithms to provide the user with reliable high resolution image superior image processing functions and system self diagnostic
VIX 1605 Online Industrial X-ray Inspections system features simple installation, operation convenient and easy maintenance
It is an ideal inspection system to inspect Aluminum casting for large volume. It is totally customized system and can be designed as per customer’s requirements. |
| |
| |
X-Ray Generator :
KV Range: 60 – 160 Kvp.
mA Range: 1 – 5 mA.
Micro processor based control.
X-Ray receiver :
4”, 6”, 9” field of view.
Mechanicals : (Optional)
Complete radiation leakage proof cabinet.
Mechanical movements of job in 5 axes.
Rotation of job: Clockwise, Anti clockwise.
Memory Systems :
Hardware :
Computer : Processor - Intel core 2 Duo, RAM – 2 GB, HDD – 80 GB, Combo drive, 2 x 19” TFT Flat panel monitors for better imaging quality.
Software Features :
Customized data base as per requirement.
Brightness adjustment.
Contrast adjustment.
Noise removal filters: Median, Gaussian, etc.
Zoom.
Pan.
Smooth, Sharpen.
Invert (Negative).
Import / Export images.
|
| |
|
| |
| |
|
| |
• Voltage Range : 20 - 450KV
• Current Range : 0 - 16mA
• Focus : Dual Focus
• Steps of current change : 0.1mA
• Steps of voltage change : 0.5KV
• Accuracy : + / - 1%
• Maximum Power : 4500W
• Inherent Filtration : 3.0mm + 2.0mm Be
• Target Angle : 11°
• Cooling Medium : Oil
• Cooling Medium Flow : 14ltr/m
• HV Cables : 15m
• High voltage connector type : R28
• Laser beam centering device : Align the X-ray beam centerline with the
axis of object.
• Safety Features :
a) Door closer switch
b) Radiation ON indication lamp
c) Emergency OFF
d) Radiation leakage monitoring system
e) Safety alarm for temperature
• Leakage Radiation : Less than 5mSv/h at 1m at full load
• Collimator : Motorized movements
• Power Requirement : 1f / 3f, 220/440V, 50Hz |
| |
| |
|
| |
|
| |
|
| |
|
| |
|
| |
|
|
|